Product Name: PA66 flexible conduit
Material: Polyamide 66
Pipe size: AD7-AD106
Brand Name: HXYY
Place of Origin: Zhejiang, China
Application: Motors, Railway locomotive, Electrical equipment
Premium PA66 Corrugated Conduit – Engineered for Maximum Cable Protection & Longevity
Our corrugated conduit is manufactured from 100% virgin BASF PA66 nylon resin, delivering exceptional mechanical strength, thermal stability, and flame resistance. It’s the ideal solution for protecting sensitive wires and cables in industrial automation, automotive wiring, outdoor electrical systems, and heavy machinery applications.
・ Our Benefit: Our pure BASF PA66 material ensures consistent quality, superior toughness, and long-term durability. You avoid unexpected failures, reduce replacement labor, and enjoy peace of mind for years to come.
・ Your Pain Point: Standard PE/PP conduits degrade rapidly under sunlight, becoming brittle and cracking within 1-2 years, especially in harsh outdoor environments.
・ Our Benefit: Our anti-UV formulation preserves conduit integrity for 5-8+ years under direct sunlight, rain, and temperature fluctuations. Perfect for solar farms, street lighting, and outdoor machinery, eliminating the need for frequent maintenance.
・ Your Pain Point: Non-flame-retardant conduits can fuel electrical fires, putting your equipment, facilities, and reputation at risk.
・ Our Benefit: Meets 94 V1 flame retardancy standards – self-extinguishes within seconds, preventing flame spread. It acts as a critical safety barrier, protecting your wiring and minimizing fire hazards in industrial and automotive settings.
・ Your Pain Point: Conduits soften or become brittle in high/low temperature zones (e.g., engine bays, factory floors), losing their protective function and causing cable damage.
・ Our Benefit: Operates reliably from -40°C to 125°C (short-term up to 150°C). Maintains shape and strength in extreme heat or cold, ensuring continuous cable protection without deformation.
・ Your Pain Point: Thin-walled conduits flatten under heavy loads (e.g., underground burial, vehicle traffic), crushing cables and causing signal loss or short circuits.
・ Our Benefit: The corrugated structure provides exceptional rigidity and crush resistance. It withstands mechanical pressure and ground loads, keeping your cables fully protected and maintaining unobstructed wiring pathways.
・ Your Pain Point: Rigid conduits are difficult to route around obstacles, increasing installation time and labor costs.
・ Our Benefit: The corrugated design offers excellent flexibility, allowing easy bending and routing in tight spaces. It works seamlessly with standard fittings, reducing installation time and simplifying complex wiring projects.
Specifications
| Product Name | PA66 flexible conduit |
| Material | Polyamide 66 |
| Pipe size | AD7-AD106 |
| Brand Name | Solithos |
| Place of Origin | Zhejiang, China |
| Application | Motors, Railway locomotive, Electrical equipment |
| Feature | Wire protection |
| Color | Black in stock ,other color need be customized |
| Customization | Open type |
| Unit of measurement | Meter |
| Certification | ISO9001,CE,RoHS,94-V1,SGS |
| Working temperature | -40℃~+125℃ short term 140℃ |
| MOQ | 100 meters |
| Production capacity | 5000,000 meters/month |
| HS code | 3917310000 |
Applications



A: Our standard conduit is crafted from high-quality PA66 (Nylon 66) , with PP/PE material options available for custom orders.
PA66 delivers exceptional abrasion resistance, UV aging resistance, chemical corrosion resistance, and wide temperature adaptability (-40℃ to 125℃ for long-term use). With superior electrical insulation, it reliably shields internal cables from mechanical damage, moisture, and harsh environmental erosion, ensuring long-lasting performance for your projects.
Q2: Where can the conduit be used?
A: It is the ideal cable protection solution for:
✅ Industrial automation & machinery wiring
✅ Automotive & new energy vehicle harness protection
✅ Electrical control cabinets & rail transit systems
✅ Outdoor engineering, photovoltaic & wind power projects
✅ Construction, mining & other harsh industrial scenarios
Q3: How do I choose the right size conduit for my cables?
A: Select based on the nominal inner diameter , and leave a 10%-15% threading margin for easy installation.For example:
AD10 (ID 6.5mm) fits cables ≤5.5mm
AD25 (ID 20mm) fits cables ≤18mmWe offer a full size range from AD7.0 to AD106, covering everything from thin signal wires to high-power power cables, with custom sizes available for special needs.
Q4: Can you customize the conduit to my specific requirements?
A: Absolutely!
We support full customization to match your project needs:
①Color: Standard black, customizable gray, yellow, blue & more
②Length: Standard 100m/roll, customizable 50m/200m or cut-to-length
③Special designs: Split type, high-temperature resistant,etc.We also accept OEM/ODM orders for private labeling and brand customization.
Q5: Do your products have international certifications for export?
A: Yes! All our conduits are fully certified with RoHS, CE, ISO9001,UV , complying with EU, North American and global safety & environmental standards. We provide complete material certificates, test reports and inspection documents to ensure smooth customs clearance and pass customer factory audits, eliminating export risks for you.
Q6: How easy is the installation? What accessories do I need?
A: Installation is fast and tool-free! Simply thread the cables through the conduit and secure with matching cable glands (cable connectors) , or use pipe clamps/brackets for fixed routing. We offer a full line of matching accessories (nylon cable glands, quick connectors, mounting brackets, etc.) for one-stop procurement, saving you time and cost on sourcing.
Q7: How long is the service life of your conduit? Is it suitable for outdoor use?
A: Our PA66 conduit has a 10+ year service life in indoor environments. For outdoor use, our UV-stabilized weather-resistant models resist UV radiation, wind, rain and extreme temperatures, preventing brittleness, cracking and aging even after long-term outdoor exposure, ensuring reliable performance in all weather conditions.
Q8: Do you offer flame-retardant conduit? What is the flame retardant rating?
A: We provide UL94 V-0 rated flame-retardant PA corrugated conduits , which are self-extinguishing and prevent fire spread. They are specially designed for high-safety scenarios like rail transit, new energy, fire protection and electrical control systems, with complete flame retardant test reports available for verification.
Q9: What is your MOQ and lead time? Can I place a trial order?
A: We support flexible order terms for global buyers:
✅ Low MOQ: As low as 1 roll for standard specifications, perfect for trial orders
✅ Custom MOQ: Adjusted based on your custom requirements
✅ Fast lead time: 3-7 days for standard bulk orders, with negotiated schedules for large orders
✅ Partial delivery: Available for large foreign trade orders to meet your urgent needs
Q10: What packaging and shipping options do you offer?
A: We provide professional export-grade packaging and flexible logistics solutions:
①Standard packaging: Waterproof woven bag + carton, with independent bundling for each roll to prevent damage
②Custom packaging: Neutral packaging, private labeling, shipping marks available for your brand
③Logistics: Sea freight, air freight, express delivery (DHL, FedEx, etc.)
④Trade terms: FOB, CIF, DDP, EXW and more, to meet your shipping needs